• 中文核心期刊要目总览
  • 中国科技核心期刊
  • 中国科学引文数据库(CSCD)
  • 中国科技论文与引文数据库(CSTPCD)
  • 中国学术期刊文摘数据库(CSAD)
  • 中国学术期刊(网络版)(CNKI)
  • 中文科技期刊数据库
  • 万方数据知识服务平台
  • 中国超星期刊域出版平台
  • 国家科技学术期刊开放平台
  • 荷兰文摘与引文数据库(SCOPUS)
  • 日本科学技术振兴机构数据库(JST)
CHEN Qian-Qian, GUO Jian-Ru, FENG Suo-Ming, WANG Cai-Yun, ZHANG Wei. Quantitation of ligupurpurosides B and C in rat plasma using HPLC-MS/MS[J]. 中国天然药物, 2016, 14(6): 473-480.
引用本文: CHEN Qian-Qian, GUO Jian-Ru, FENG Suo-Ming, WANG Cai-Yun, ZHANG Wei. Quantitation of ligupurpurosides B and C in rat plasma using HPLC-MS/MS[J]. 中国天然药物, 2016, 14(6): 473-480.
CHEN Qian-Qian, GUO Jian-Ru, FENG Suo-Ming, WANG Cai-Yun, ZHANG Wei. Quantitation of ligupurpurosides B and C in rat plasma using HPLC-MS/MS[J]. Chinese Journal of Natural Medicines, 2016, 14(6): 473-480.
Citation: CHEN Qian-Qian, GUO Jian-Ru, FENG Suo-Ming, WANG Cai-Yun, ZHANG Wei. Quantitation of ligupurpurosides B and C in rat plasma using HPLC-MS/MS[J]. Chinese Journal of Natural Medicines, 2016, 14(6): 473-480.

Quantitation of ligupurpurosides B and C in rat plasma using HPLC-MS/MS

Quantitation of ligupurpurosides B and C in rat plasma using HPLC-MS/MS

  • 摘要: The present study was designed to develop a sensitive and selective specific high performance liquid chromatography (HPLC)-tandem mass spectrometric method (MS/MS) for the determination of ligupurpurosides B and C in rat plasma. The samples were prepared after protein precipitation and analyzed by liquid chromatography equipped with a C18 column interfaced with a triple quadrupole tandem mass spectrometer using ESI as the ionization source in the negative ion mode. The mobile phase consisted of water (0.01% formic acid)-methanol (57:43, V/V) at the flow rate of 0.3 mLmin-1. The analytes and internal standard acteoside were both detected by use of multiple reaction monitoring mode. The total run time was 6.0 min. The method was linear in the concentration range of 2.5-500.0 ngmL-1 and the lower limit of quantification (LLOQ) was 2.5 ngmL-1. The intra-day and inter-day relative standard deviations across three validation runs over the entire concentration range were less than 9.8%. The accuracy determined at three concentrations was within 6.1% in terms of relative error. In conclusion, this assay offers advantages in terms of expediency and suitability for the analysis of ligupurpuroside B and ligupurpuroside C in various biological fluids.

     

    Abstract: The present study was designed to develop a sensitive and selective specific high performance liquid chromatography (HPLC)-tandem mass spectrometric method (MS/MS) for the determination of ligupurpurosides B and C in rat plasma. The samples were prepared after protein precipitation and analyzed by liquid chromatography equipped with a C18 column interfaced with a triple quadrupole tandem mass spectrometer using ESI as the ionization source in the negative ion mode. The mobile phase consisted of water (0.01% formic acid)-methanol (57:43, V/V) at the flow rate of 0.3 mLmin-1. The analytes and internal standard acteoside were both detected by use of multiple reaction monitoring mode. The total run time was 6.0 min. The method was linear in the concentration range of 2.5-500.0 ngmL-1 and the lower limit of quantification (LLOQ) was 2.5 ngmL-1. The intra-day and inter-day relative standard deviations across three validation runs over the entire concentration range were less than 9.8%. The accuracy determined at three concentrations was within 6.1% in terms of relative error. In conclusion, this assay offers advantages in terms of expediency and suitability for the analysis of ligupurpuroside B and ligupurpuroside C in various biological fluids.

     

/

返回文章
返回